Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
calculation (if not (Q)SAR)
Remarks:
estimated by calculation
Adequacy of study:
key study
Study period:
July 2006
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Remarks:
In the TGD it is stated that the vapour pressure needs not to be measured, if calculations indicate that the value is significantly less than 10E-5 Pa.
Qualifier:
no guideline followed
Principles of method if other than guideline:
- Software tool(s) used including version: Epi v3.12, 2006.
Key result
Temp.:
25 °C
Vapour pressure:
ca. 0 Pa
Remarks on result:
other: Estimation
Conclusions:
The substance has a calculated Vapour pressure of 1.06*10^-9 Pa @ 25ºC
Executive summary:

The Vapour Pressure of tosylchloramide sodium was calculated to be 1.06*10 ^-9 Pa @ 25ºC using EpiWin sofware

Description of key information

tosylchloramide sodium has a calculated vapour pressure of 1.06 x 10^-9 Pa at 25ºC

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information