Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
without GLP but in the spirit of GLP
Justification for type of information:
Guideline study under GLP
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 48654
- Expiration date of the lot/batch: 2020 May 17
- Purity test date: Not reported


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature
- Stability under test conditions: assumed to be stable
- Solubility and stability of the test substance in the solvent/vehicle: N/A
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: N/A

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: used as received
- Preliminary purification step (if any): N/A
- Final dilution of a dissolved solid, stock liquid or gel: N/A
- Final preparation of a solid: N/A

FORM AS APPLIED IN THE TEST (if different from that of starting material)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)

OTHER SPECIFICS:
Key result
Test procedure:
burning time (test type not further specified)
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
GHS criteria not met
Conclusions:
Test substance did not ignite within the two minute time period. Test substance melted to a distance of 30mm. The test substance was determined to be not highly flammable.

Description of key information

No ignition or propagation of flame

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Experimentally tested and found to be non-flammable.

Justification for classification or non-classification

The substance was experimentally not determined to be flammable. The criteria for flammability according to Regulation EC No. 1272/2008 are not met.