Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 October 2016 - 12 October 2016
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
At time "0" 16 mL of synthetic sewage was diluted to 250 mL with water and 250 mL of inoculum added in a 500 mL conical flask (first control). The mixture was aerated with clean, oil-free compressed air via narrow bore glass tubes at a rate of 0.5 to 1.0 liter per minute. Thereafter, at 15 minute intervals the procedure was repeated for the second control followed by the reference item vessels with appropriate amounts of the reference item being added. The test item vessels were prepared. Finally two further control vessels were prepared. The test was conducted under normal laboratory lighting in a temperature controlled room at measured temperatures of between 20 and 21 ºC.
Test organisms (species):
activated sludge
Details on inoculum:

- Name and location of sewage treatment plant where inoculum was collected: Severn Trent Water Plc sewage treatment plant at Loughborough, Leicestershire, UK

- Preparation of inoculum for exposure:The activated sewage sludge sample was maintained on continuous aeration in the laboratory at a temperature of approximately 21 ºC and was used on the day of collection. The pH of the sample was 7.5 measured using a Hach HQ40d Flexi handheld meter. Determination of the suspended solids level of the activated sewage sludge was carried out by filtering a sample (100 mL) of the activated sewage sludge by suction through a pre-weighed GF/A filter paper* using a Buchner funnel which was then rinsed 3 times with 10 mL of deionized reverse osmosis water and filtration continued for 3 minutes. The filter paper was then dried in an oven at approximately 105 ºC for at least one hour and allowed to cool before weighing. This process was repeated until a constant weight was attained. The suspended solids concentration was equal to 3.0 g/L.
Test type:
not specified
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Hardness:
The test water used for the test was deionized reverse osmosis water containing less than 1 mg/L Dissolved Organic Carbon (DOC).
Test temperature:
The test was conducted under normal laboratory lighting in a temperature controlled room at measured temperatures of between 20 and 21 ºC.
pH:
The pH of the sample was 7.5 measured using a Hach HQ40d Flexi handheld meter.
Dissolved oxygen:
The dissolved oxygen concentrations after 30 minutes contact time in all vessels were above 60 to 70% of the dissolved oxygen saturation level of 8.9 mg O2/L.
Nominal and measured concentrations:
10, 100 and 1000 mg/L
Details on test conditions:
At time "0" 16 mL of synthetic sewage was diluted to 250 mL with water and 250 mL of inoculum added in a 500 mL conical flask (first control). The mixture was aerated with clean, oil-free compressed air via narrow bore glass tubes at a rate of 0.5 to 1.0 liter per minute. Thereafter, at 15 minute intervals the procedure was repeated for the second control followed by the reference item vessels with appropriate amounts of the reference item being added. The test item vessels were prepared as described in Section 3.3.1.1. Finally two further control vessels were prepared. The test was conducted under normal laboratory lighting in a temperature controlled room at measured temperatures of between 20 and 21 ºC.
Reference substance (positive control):
yes
Key result
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
Range-Finding Test
The dissolved oxygen concentrations in all vessels after 30 minutes contact time are given in Table2. Oxygen consumption rates and percentage inhibition values for the control, test and reference item after 3 hours contact time are given in Table 3. The pH values of the test preparations at the start and end of the exposure period are given in Table 4. Observations made on the test preparations throughout the range-finding test are given in Table 5. The dissolved oxygen concentrations after 30 minutes contact time in all vessels were above 60 to 70% of the dissolved oxygen saturation level of 8.9 mg O2/L. No statistically significant toxic effects were shown at all of the test concentrations employed. It was therefore considered justifiable not to perform a definitive test. It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L. Percentage inhibition is plotted against concentration for the reference item, 3,5-dichlorophenol.

In some instances, the initial and final dissolved oxygen concentrations were outside those recommended in the test guidelines (7 mg O2/L and 2 mg O2/L respectively). This was considered to have had no adverse effect on the results of the study given that in all cases the oxygen consumption rate was determined over the linear portion of the oxygen consumption trace..
Results with reference substance (positive control):

The reference item gave a 3-Hour EC50 value of 6.0 mg/L, 95% confidence limits 4.5 to 8.0 mg/L.
Validity criteria fulfilled:
yes
Conclusions:
The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50 value of greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L.
Executive summary:

Introduction

A study was performed to assess the effect of the test item on the respiration of activated sewage sludge. The method followed was designed to be compatible with the OECD Guidelines for Testing of Chemicals (2010) No. 209 "Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation)".

Methods

Activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 10, 100 and 1000 mg/L (3 replicates of the 1000 mg/L test concentration) for a period of 3 hours at measured temperatures of between 20 and 21 °C with the addition of a synthetic sewage as a respiratory substrate.

The rate of respiration was determined after 3 hours contact time and compared to data for the control and a reference item, 3,5-dichlorophenol.

Results

The effect of the test item on the respiration of activated sewage sludge gave a 3-Hour EC50 value of greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L.

It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L.

The reference item gave a 3-Hour EC50 value of 6.0 mg/L, 95% confidence limits 4.5 to 8.0 mg/L.

Description of key information

The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50 value of greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L.

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
1 000 mg/L