Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental start date 03 May 2017. Experimental completion date 03 May 2017.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
3',5'-di-tert-butyl-3-{5-tert-butyl-2-[3-(4-tert-butyl-2-{3',5'-di-tert-butyl-2-hydroxy-5-methyl-[1,1'-biphenyl]-3-yl}phenoxy)propoxy]phenyl}-5-methyl-[1,1'-biphenyl]-2-ol
EC Number:
600-548-6
Cas Number:
1042662-40-7
Molecular formula:
C65H84O4
IUPAC Name:
3',5'-di-tert-butyl-3-{5-tert-butyl-2-[3-(4-tert-butyl-2-{3',5'-di-tert-butyl-2-hydroxy-5-methyl-[1,1'-biphenyl]-3-yl}phenoxy)propoxy]phenyl}-5-methyl-[1,1'-biphenyl]-2-ol
Specific details on test material used for the study:
Identification: 2,2'-[propane-1,3-diylbis(oxy)]bis(3",5,5"-tri-tert-butyl-5'-methyl-1,1':3',1"-terphenyl-2’-ol)
Batch: 1502501005
CAS number: 1042662-40-7
Purity: 100%
Physical state/Appearance: Sponsor solid powder, white, odorless Envigo white powder
Expiry Date: 01 February 2025
Storage Conditions: room temperature in the dark

Test animals / tissue source

Species:
cattle
Details on test animals or tissues and environmental conditions:
Source of Bovine Eyes
Eyes from adult cattle (typically 12 to 60 months old) were obtained from a local abattoir as a by-product from freshly slaughtered animals. The eyes were excised by an abattoir employee after slaughter, and were placed in Hanks’ Balanced Salt Solution (HBSS) supplemented with antibiotics (penicillin at 100 IU/mL and streptomycin at 100 μg/mL). They were transported to the test facility over ice packs on the same day of slaughter. The corneas were prepared immediately on arrival.

Test system

Vehicle:
other: sodium chloride solution 0.9% w/v
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
0.75 mL of the test item preparation. For the purpose of this study the test item was prepared as a 20% w/v solution in sodium chloride 0.9% w/v.
0.75 mL of the Negative control. The negative control item, sodium chloride 0.9% w/v, was used as supplied.
0.75 mL of the Positive control. The positive control item, Imidazole, was used as a 20% w/v solution in sodium chloride 0.9% w/v.
Duration of treatment / exposure:
240 minutes
Duration of post- treatment incubation (in vitro):
90 minutes
Number of animals or in vitro replicates:
3
Details on study design:
Preparation of Corneas
All eyes were macroscopically examined before and after dissection. Only corneas free of damage were used.
The cornea from each selected eye was removed leaving a 2 to 3 mm rim of sclera to facilitate handling. The iris and lens were peeled away from the cornea. The isolated corneas were immersed in a dish containing HBSS until they were mounted in Bovine Corneal Opacity and Permeability (BCOP) holders.
The anterior and posterior chambers of each BCOP holder were filled with complete Eagle’s Minimum Essential Medium (EMEM) without phenol red and plugged. The holders were incubated at 32 ± 1 ºC for 60 minutes. At the end of the incubation period each cornea was examined for defects. Only corneas free of damage were used.

Selection of Corneas and Opacity Reading
The medium from both chambers of each holder was replaced with fresh complete EMEM.
A pre-treatment opacity reading was taken for each cornea using a calibrated opacitometer. The average opacity for all corneas was calculated.
Three corneas with opacity values close to the median value of all corneas were allocated to the negative control. Three corneas were also allocated to the test item and three corneas to the positive control item.

Treatment of Corneas
The EMEM was removed from the anterior chamber of the BCOP holder and 0.75 mL of the test item preparation or control items were applied to the appropriate corneas. The holders were gently tilted back and forth to ensure a uniform application of the item over the entire cornea. Each holder was incubated, anterior chamber uppermost, at 32 ± 1 ºC for 240 minutes.
At the end of the exposure period the test item and control items were removed from the anterior chamber and the cornea was rinsed three times with fresh complete EMEM containing phenol red before a final rinse with complete EMEM without phenol red. The anterior chamber was refilled with fresh complete EMEM without phenol red. A post-treatment opacity reading was taken and each cornea was visually observed.

Application of Sodium Fluorescein
Following the opacity measurement the permeability of the corneas to sodium fluorescein was evaluated. The medium from the anterior chamber was removed and replaced with 1 mL of sodium fluorescein solution (5 mg/mL). The dosing holes were plugged and the holders incubated, anterior chamber uppermost, at 32 ± 1 ºC for 90 minutes.

Permeability Determinations
After incubation the medium in the posterior chamber of each holder was decanted and retained.
1.0 mL of media representing each cornea was dispensed into separate 1.5 mL cuvettes, with 1.0 mL complete EMEM being used for blank correction. Optical density at 492 nm (OD492) was measured using the Camspec Model M108 Spectrophotometer.

Histopathology
The corneas were retained after testing for possible conduct of histopathology. Each cornea was placed into a pre-labeled tissue cassette fitted with a histology sponge to protect the endothelial surface. The cassette was immersed in 10% neutral buffered formalin.

Results and discussion

In vitro

Results
Irritation parameter:
in vitro irritation score
Run / experiment:
Mean
Value:
0.1
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
Corneal Epithelium Condition
The corneas treated with the test item or negative control item were clear post treatment. The corneas treated with the positive control item were cloudy post treatment.

Criteria for an Acceptable Test
The positive control In Vitro Irritancy Score was within the range of 50.8 to 100.4. The positive control acceptance criterion was therefore satisfied.
The negative control gave opacity of ≤5.4 and permeability ≤0.070. The negative control acceptance criteria were therefore satisfied.

Any other information on results incl. tables

Individual and Mean Corneal Opacity and Permeability Measurements

Treatment

Cornea Number

Opacity

Permeability (OD)

In VitroIrritancy Score

Pre-Treatment

Post-Treatment

Post-Treatment-Pre‑Treatment

Corrected Value

 

Corrected Value

Negative Control

7

3

4

1

 

0.023

 

 

8

3

5

2

 

0.060

 

 

9

3

2

0

 

0.073

 

 

 

 

 

1.0*

 

0.052~

 

1.8

Positive
Control

1

3

70

67

66.0

0.999

0.947

 

2

3

78

75

74.0

1.624

1.572

 

3

2

70

68

67.0

0.951

0.899

 

 

 

 

 

69.0#

 

1.139#

86.1

Test Item

4

3

3

0

0.0

0.050

0.000

 

5

2

2

0

0.0

0.007

0.000

 

6

2

2

0

0.0

0.079

0.027

 

 

 

 

 

0.0#

 

0.009#

0.1

OD= Optical density           

* = Mean of the post-treatment -pre‑treatment values             

~= Mean permeability                    

#= Mean corrected value               

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
No category. Not requiring classification to UN GHS or EU CLP.
Executive summary:

Introduction

The purpose of this test was to identify test items that can induce serious eye damage and to identify test items not requiring classification for eye irritation or serious eye damage. The Bovine Corneal Opacity and Permeability (BCOP) test method is an organotypic model that provides short-term maintenance of normal physiological and biochemical function of the bovine cornea in vitro. In this test method, damage by the test item is assessed by quantitative measurements of changes in corneal opacity and permeability.

The test method can correctly identify test items (both chemicals and mixtures) inducing serious eye damage as well as those not requiring classification for eye irritation or serious eye damage, as defined by the United Nations (UN) Globally Harmonized System of Classification and Labelling of Items (GHS) and EU Classification, Labelling and Packaging (CLP) of chemicals (Regulation (EC) No 1272/2008), and it was therefore endorsed as scientifically valid for both purposes. Test items inducing serious eye damage are classified as UN GHS and EU CLP Category 1. Items not classified for eye irritation or serious eye damage are defined as those that do not meet the requirements for classification as UN GHS/EU CLP Category 1 or 2 (2A or 2B), i.e. they are referred to as UN GHS/EU CLP No Category.

Method

The test item was applied neat for 240 minutes. Negative and positive control items were tested concurrently. The two endpoints, decreased light transmission through the cornea (opacity) and increased passage of sodium fluorescein dye through the cornea (permeability) were combined in an empirically derived formula to generate an In Vitro Irritancy Score (IVIS).

Data Interpretation

The test item is classified according to the prediction model as follows:

IVIS

Classification

≤ 3

No category. Not requiring classification to UN GHS or EU CLP

> 3; ≤55

No prediction of eye irritation can be made

> 55

Category 1. UN GHS or EU CLP Causes serious eye damage

Results

The In Vitro irritancy scores are summarized as follows:

Treatment

In VitroIrritancy Score

Test Item

0.1*

Negative Control

1.8

Positive Control

86.1

*=   The test item could not be formulated to a concentration of 20% w/v in sodium chloride 0.9% w/v

Conclusion

No category. Not requiring classification to UN GHS or EU CLP.