Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011-08-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
> 600 °C
Atm. press.:
ca. 1 013 hPa
Decomposition:
no
Sublimation:
no
Remarks on result:
other: No melting point up to 600 °C observed. No mass loss or any endo- or exothermic effects detected.
Conclusions:
The test item has no melting point up to 600 °C under atmospheric conditions.
Executive summary:

No melting point was observed for the test item in a Differential Scanning Calorimentry measurement according to EU A.1 up to 600 °C. The test item remained unchanged.

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2011-08-05
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
no
Type of method:
other: Differential Scanning Calorimetry (DSC)
Key result
Melting / freezing pt.:
> 600 °C
Atm. press.:
ca. 1 013 hPa
Decomposition:
no
Sublimation:
no
Remarks on result:
other: No melting point up to 600 °C observed, no mass loss or any endo- or exothermic effects detected
Conclusions:
The test item has no melting point up to 600 "C under atmospheric conditions.
Executive summary:

No melting point was observed for the test item in a Differential Scanning Calorimentry measurement according to EU A.1 up to 600 °C. The test item remained unchanged.

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2011-08-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
no
Type of method:
other: Differential Scanning Calorimetry (DSC)
Key result
Melting / freezing pt.:
> 600 °C
Atm. press.:
ca. 1 013 hPa
Decomposition:
no
Sublimation:
no
Remarks on result:
other: No melting point up to 600 °C observed. No mass loss or any endo- or exothermic effects detected.
Conclusions:
The test item has no melting point up to 600 °C under atmospheric conditions.
Executive summary:

No melting point was observed for the test item in a Differential Scanning Calorimentry measurement according to EU A.1 up to 600 °C. The test item remained unchanged.

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2011-08-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
no
Type of method:
other: Differential Scanning Calorimetry (DSC)
Key result
Melting / freezing pt.:
> 600 °C
Atm. press.:
ca. 1 013 hPa
Decomposition:
no
Sublimation:
no
Remarks on result:
other: No melting point up to 600 °C observed. No mass loss or any endo- or exothermic effects detected.
Conclusions:
The test item has no melting point up to 600 "C under atmospheric conditions.
Executive summary:

No melting point was observed for the test item in a Differential Scanning Calorimentry measurement according to EU A.1 up to 600 °C. The test item remained unchanged.

Description of key information

In the key study no melting point up to 600°C was observed, the test item remained unchanged.

This result was confirmed by all supporting studies.

Key value for chemical safety assessment

Additional information