Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Qualifier:
according to guideline
Guideline:
other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.6: Recommendations on the Transport of Dangerous Goods, Part III: Classification Procedures, Test Methods and Criteria Relating to Class 2, 3, 4, Division 5.1, Class 8 and 9, Paragraph 32.4.1
Version / remarks:
2015
Qualifier:
according to guideline
Guideline:
other: ASTM International, ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Version / remarks:
2012
GLP compliance:
yes
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Trimethyl orthoacetate
EC Number:
215-892-9
EC Name:
Trimethyl orthoacetate
Cas Number:
1445-45-0
Molecular formula:
C5H12O3
IUPAC Name:
1,1,1-trimethoxyethane

Results and discussion

Flash point
Flash point:
18 °C
Atm. press.:
1 013.25 mBar

Applicant's summary and conclusion