Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-05-24
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch No.of test material: S61254001
- Expiration date of the lot/batch: 2018-07-10
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Interpretation of results:
GHS criteria not met
Conclusions:
The test item has no explosive properties according to the definition in Regulation EC No. 440/2008 Method A.14.

Description of key information

The test item has no explosive properties according to the definition in Regulation EC No. 440/2008 Method A.14.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

The explosive properties of the test item were tested according to Regulation EC No. 440/2008 Method A.14 with respect to thermal (flame; Koenen Test) and mechanical (impact) sensitivity. The test item was not thermally sensitive or sensitive to mechanical shock and hence is not considered to be explosive.

Justification for classification or non-classification

The test item did not exhibit explosive properties in a test conducted according to Regulation EC No. 440/2008 Method A.14 and is therefore does not require classification for explosiveness.