Registration Dossier

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
other: other company data
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: other company data
Qualifier:
equivalent or similar to
Guideline:
other: ISO/ASTM/OECD procedure or Industry internal technical procedure (or OECD 103)
Principles of method if other than guideline:
Industry internal technical procedure generally based on ISO, ASTM or OECD method
GLP compliance:
no
Type of method:
ebulliometer
Key result
Boiling pt.:
> 162 - < 164 °C
Atm. press.:
ca. 0.667 hPa
Decomposition:
no
Remarks on result:
other:
Remarks:
reported at 5 mm Hg.
Key result
Boiling pt.:
487 °C
Atm. press.:
101.3 kPa
Decomposition:
no
Remarks on result:
other: converted to 760 mm Hg = 101.3 kPa
Conclusions:
The boiling point of the test material is estimated to be 487 °C at 101.3 kPa (or 760 mm Hg). The original data is reported at 162-164 °C at reduced pressure of 5 mm Hg.

Description of key information

487 °C (est.) at 101.3 kPa; reported as 162-164 °C at reduced pressure (0.667 kPa).

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
487 °C

Additional information

487°C (est.) at 101.3 kPa;162-164 °C at reduced pressure (0.667 kPa or 5 mm Hg),