Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
yes (incl. QA statement)
Type of method:
method according to Siwoloboff

Test material

Constituent 1
Reference substance name:
Resin acids and Rosin acids, fumarated, esters with pentaerythritol
EC Number:
305-514-1
EC Name:
Resin acids and Rosin acids, fumarated, esters with pentaerythritol
Cas Number:
94581-15-4
IUPAC Name:
94581-15-4
Details on test material:
Test Substance Name: Resin acids and rosin acids, fumarated, reaction product with pentaerythritol
CAS No. 94581-15-4
Batch No. 0910002486
Supplied By Arizona Chemicals
Description: Pale yellow solid.

Results and discussion

Boiling point
Decomposition:
yes
Decomp. temp.:
>= 163 °C

Any other information on results incl. tables

Apparatus : Boiling temperature device with liquid bath and thermometer.

 Run Number Mass of sample Used  (g)  Boiling Temperature (g)
 1  0.344  N/A
 2  0.345  N/A
 Mean Boiling Temp (°C)  N/A   

Result : Not determined

Pressure at which measurements were taken (kPa) : 102.0

At 163°C a colour change of the liquid was observed. This was suspected to be decomposition of the sample and the test was therefore terminated.

Applicant's summary and conclusion

Conclusions:
Result : Not determined

At 163°C a colour change of the liquid was observed. This was suspected to be decomposition of the sample and the test was therefore terminated.