Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vivo
Type of information:
migrated information: read-across based on grouping of substances (category approach)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study with acceptable restrictions (lack of data on test substance and animal husbandry).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1991
Report date:
1991

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 405 (Acute Eye Irritation / Corrosion)
Deviations:
yes
Remarks:
(lack of details on test substance and animal husbandry)
GLP compliance:
not specified

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): pentaerythritol C7-C10 tetraester
- Analytical Purity:according to the manufacturer, the test was conducted with the pure substance without the addition of any substances.

Test animals / tissue source

Species:
rabbit
Strain:
New Zealand White
Details on test animals or tissues and environmental conditions:
TEST ANIMALS
- Weight at study initiation: 3.6 - 4.6 kg

Test system

Vehicle:
unchanged (no vehicle)
Controls:
not required
Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 0.1 mL

Duration of treatment / exposure:
single application without washing
Observation period (in vivo):
3 d
Number of animals or in vitro replicates:
3 females
Details on study design:
SCORING SYSTEM: Draize scoring system

Results and discussion

In vivo

Resultsopen allclose all
Irritation parameter:
cornea opacity score
Basis:
mean
Remarks:
out of all three animals
Time point:
other: mean over 24 h, 48 h and 72 h
Score:
0
Max. score:
4
Reversibility:
other: reversibility not applicable
Irritation parameter:
iris score
Basis:
mean
Remarks:
out of all three animals
Time point:
other: mean over 24 h, 48 h and 72 h
Score:
0
Max. score:
2
Reversibility:
other: reversibility not applicable
Irritation parameter:
conjunctivae score
Basis:
mean
Remarks:
out of all three animals
Time point:
other: mean over 24 h, 48 h and 72 h
Score:
0
Max. score:
3
Reversibility:
other: reversibility not applicable
Irritation parameter:
chemosis score
Basis:
mean
Remarks:
out of all three animals
Time point:
other: mean over 24 h, 48 h and 72 h
Score:
0
Max. score:
4
Reversibility:
other: reversibility not applicable
Irritant / corrosive response data:
No corneal or iridial effects were observed. Conjunctival effects included slight redness (1 animal) and slight discharge (1 animal) and were transiently seen approx. 1 h after dosing.

Applicant's summary and conclusion

Interpretation of results:
not irritating
Remarks:
Migrated information Criteria used for interpretation of results: EU
Conclusions:
CLP: not classified
DSD: not classified