Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11th April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: The test item was observed to melt at point of contact with the burner flame, but did not ignite. As there was no flame or propagation of flame along the train, no further testing was necessary.
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test was determined to be not highly flammable.
Executive summary:

The flammability of the test item was determined in a EU Method A.10 guideline study. The test item was observed to melt at point of contact with the burner flame, but did not ignite. As there was no flame or propagation of flame along the train, no further testing was necessary. The test item was determined to be not highly flammable.

The study is a GLP compliant guideline experimental study fully acceptable for this endpoint.

Description of key information

The test item was determined to be not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test item was determined in a EU Method A.10 guideline study (Dunning 2018). The test item was observed to melt at point of contact with the burner flame, but did not ignite. As there was no flame or propagation of flame along the train, no further testing was necessary. The test item was determined to be not highly flammable.

The study is a GLP compliant guideline experimental study fully acceptable for this endpoint.

Justification for classification or non-classification

The test item was found to be not highly flammable, therefore, the test item does not require a flammability classification.