Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
- Experience in handling (e.g. during the density study) demonstrated that the substance does not ignite spontaneously on coming into contact with air at normal temperatures.
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the organic substance does not contain metals or metalloids and hence, the classification procedure does not need to be applied
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
The substance did not react with water during the water solubility study.
Reason / purpose:
data waiving: supporting information
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Reason / purpose:
data waiving: supporting information
Reason / purpose:
reference to other study
Endpoint:
self-heating substances / mixtures
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Justification for type of information:
Since the substance is not adsorbed onto a large surface, self-heating is not a relevant property for this substance. In general liquids are not classified as self-heating.
Reason / purpose:
data waiving: supporting information

Description of key information

No pyrophoric properties (based on experience in handling).

Not highly flammable in contact with water (based on experience in handling and structural formula).

Flammability solids and self-heating: not applicable (substance is a liquid).

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flash point: 136°C.

Justification for classification or non-classification

-Since the flash point is > 60°C, no classification is required for the CLP hazard 'Flammable liquid'.

-Based on experience in handling, no classification is required for the CLP hazard 'Pyrophoric liquids'.

-Based on experience in handling and structural formula, no classification is required for the CLP hazard 'Substances which in contact with water emits flammable gases'.

-Since the substance is not a liquid adsorbed onto a large surface, no classification is required for the CLP hazard 'self-heating'.