Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 November 2015 - 17 December 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Version / remarks:
2012
Deviations:
no
GLP compliance:
yes
Type of method:
other: modified continuously closed cup
Flash point apparatus:
other: Eraflash (Eralytics, Austria)
Specific details on test material used for the study:
Boiling point of test material: 222°C
Key result
Flash point:
136 °C
Atm. press.:
1 013 hPa

- Test 1: 136°C

- Test 2: 136°C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the substance was determined to be 136°C.
Executive summary:

The flash point at 1013 hPa was determined using the modified continuously closed cup in a GLP study according to ASTM D7094.

Description of key information

The flash point of the substance was determined to be 136°C (EC A.9, ASTM D7094: modified continuously closed cup).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
136 °C

Additional information