Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Key result
Test procedure:
burning time over 250 mm for metal powders or metal alloys
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The test item was formed into a particle train. A hot flame from a gas burner with a diameter of about 6 mm is used to ignite the pile at one end. In the preliminary screening test, the substance melts and decomposes. After removal of the gas burner the flame does not propagate along the test train. According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 the test item Aesculin has not to be considered as flammable.

 

Interpretation of results:
not classified based on GHS criteria

Description of key information

According to the definition in the Council Regulation (EC) No 440/2008 that is pursuant to Regulation (EC) No 1907/2006 the test item Aesculin has not to be considered as flammable.

 

Key value for chemical safety assessment

Flammability:
not classified

Additional information