Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 2017
Reliability:
1 (reliable without restriction)
Justification for type of information:
The flammability (solids) was determined by measuring the burning rate of test item prepared as a pile
of set dimensions. Testing was conducted using a procedure designed to be compatible with Method
A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
(±)-7-[(3-chloro-6,11-dihydro-6-methyldibenzo[c,f][1,2]thiazepin-11-yl)amino]heptanoic acid S,S-dioxide
EC Number:
276-851-9
EC Name:
(±)-7-[(3-chloro-6,11-dihydro-6-methyldibenzo[c,f][1,2]thiazepin-11-yl)amino]heptanoic acid S,S-dioxide
Cas Number:
72797-41-2
Molecular formula:
C21H25ClN2O4S
IUPAC Name:
(±)-7-[(3-chloro-6,11-dihydro-6-methyldibenzo[c,f][1,2]thiazepin-11-yl)amino]heptanoic acid S,S-dioxide
Test material form:
solid: crystalline
Details on test material:
White powder
Specific details on test material used for the study:
Batch 18114773

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
> 2 min
Remarks on result:
other: The pile melted and failed to ignite during the 2 minutes that the Bunsen flame was applied

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.