Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Qualifier:
equivalent or similar to
Guideline:
other: DIN 51757
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Abel apparatus
Key result
Flash point:
ca. 395 °C
Atm. press.:
ca. 101 325 Pa

Description of key information

the flashpoint is ca. 395°C

Key value for chemical safety assessment

Additional information