Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2017-11-07 to 2017-11-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
March 23, 2006, "Vapour Pressure: static method"
Deviations:
no
GLP compliance:
yes
Type of method:
static method
Specific details on test material used for the study:
Lot number: 707001
Purity: 98.6%
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
1.86 kPa
Key result
Test no.:
#2
Temp.:
30 °C
Vapour pressure:
2.33 kPa
Key result
Test no.:
#3
Temp.:
35 °C
Vapour pressure:
2.93 kPa

Test temperature (°C )

Vapour pressure

 

Measured value (mm Hg)

Converted value (kPa)

Average (kPa)

25

14.0

1.86

1.86

14.0

1.86

14.0

1.86

30

17.5

2.33

2.33

17.5

2.33

17.5

2.33

35

22.0

2.93

2.93

22.0

2.93

22.0

2.93

Conclusions:
The vapor pressure of the test item was found to be 1.86 kPa (25 ºC).
Executive summary:

The vapor pressure of the test item was found to be 1.86 kPa (25 ºC) in a study run to OECD Test Guideline 104 (static method).

Description of key information

The vapor pressure of the test item was found to be 1.86 kPa (25 ºC) in a study run to OECD Test Guideline 104 (static method).

Key value for chemical safety assessment

Vapour pressure:
1.86 kPa
at the temperature of:
25 °C

Additional information