Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June from 04th to 12th, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
The test item was used in its initial form.
Remarks on result:
no self ignition observed under the test conditions
Remarks:
up to 400 °C
Conclusions:
No self-ignition up to 400 °C
Executive summary:

The relative self-ignition temperature of the test item was determined with the help of the automatic auto-ignition tester, according to the EU method A.16.

A certain volume of the test item under the assay was placed into an oven at ambient temperature; the temperature/time curve was recorded while the temperature of the oven was increased up to 400 °C, at a rate of approximately 0.5 °C/min. For the purpose of this test, the temperature of the oven at which the sample temperature reaches 400 °C by self-heating is called the self-ignition temperature.

Three replicate tests were performed.

In the course of the study the test item did not self-ignite up to 400 °C. Thus, no self-ignition temperature could be stated.

Conclusion

No self-ignition up to 400 °C.

Description of key information

No self-ignition up to 400 °C

Key value for chemical safety assessment

Additional information

EU method A.16