Registration Dossier

Administrative data

First-aid measures

Consult a physician. Show this safety data sheet to the doctor in attendance.
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician
In case of skin contact take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Take
victim immediately to hospital. Consult a physician.
In case of eye contact rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with
water. Consult a physician.

Fire-fighting measures

Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Advice for firefighters
Wear self-contained breathing apparatus for firefighting if necessary.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Wear respiratory protection. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove
all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form
explosive concentrations. Vapours can accumulate in low areas.

Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the
environment must be avoided.

Methods and materials for containment and cleaning up
Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and
place in container for disposal according to local regulations

Handling and storage

The substance is an intermediate used under strictly controlled conditions.
Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic
charge
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are
opened must be carefully resealed and kept upright to prevent leakage.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Eye/face protection
Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN
166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Body Protection
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type AXBEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air
respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Stability and reactivity

The substance is stable under the normal conditions of use and storage.

Disposal considerations

Dispose waste according to local regulations.