Registration Dossier

Administrative data

Endpoint:
flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Study period:
7 - 9 Nov 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.11 (Flammability (Gases))
Deviations:
no
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 116B2018
- Physical state: colourless liquid
- Purity:96.7%
- Purity test date: 9 August 2016
- Expiration date of the lot/batch: 31 March 2018

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature (10 °C to 30 °C)

Results and discussion

Flammable gases (Lower and upper explosion limit)open allclose all
Key result
Parameter:
lower explosion limit
Remarks on result:
no flammable range with air at 20°C and 101.3 kPa
Parameter:
upper explosion limit
Remarks on result:
no flammable range with air at 20°C and 101.3 kPa

Any other information on results incl. tables

Starting at 0.5 mol-% of test item and proceeding up to 4.0 mol-% of test item, no ignition was observed. For the mixtures from 2.5 to 4.0 mol-% of test item, a formation of aerosol in the static mixer was observed.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In a flammability test of PPVE-2, no ignition was observed according to EU Method A.11.
Executive summary:

The flammability of PPVE-2 was evaluated according to EU Method A.11. This test was performed following EU guidance and was GLP compliant; therefore it is considered reliable without restriction.