Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data

Data source

Reference
Reference Type:
other: database
Title:
GSBL database_1,10 Dichlorodecane
Author:
Landesanstalt für Immissionsschutz des Landes NRW
Year:
1992
Bibliographic source:
Landesanstalt für Immissionsschutz des Landes NRW;Organismen und Stoff liste, Version 3.0;Datenbank der L I S , Essen, April 1992

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
no detailed information available but data published on a reliable database
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
other: no detailed information available but data published on a reliable database

Test material

Constituent 1
Chemical structure
Reference substance name:
1,10-dichlorodecane
EC Number:
218-489-6
EC Name:
1,10-dichlorodecane
Cas Number:
2162-98-3
Molecular formula:
C10H20Cl2
IUPAC Name:
1,10-dichlorodecane
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
ca. 146 °C
Remarks on result:
other: no detailed information on pressure are available but data published on a reliable database

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Under the study conditions, the flash point of the test substance was 146°C.


Executive summary:

A study was conducted to determine the flash pointt of the test substance but no data was available regarding the methodology. Under the study conditions, the flash pointt of the test substance was 146°C.