Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From January 10,2017 to January 30,2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid: viscous
Specific details on test material used for the study:
Aspect : clear, nearly colourless to lightly-yellow, highly viscous liquid

- Sample tested


Lot No. : 75518

Purity : 95.7%

Expiration date : September 19, 2018

Results and discussion

Flash point
Key result
Flash point:
248 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of Panthenyltriacetate was determined by the Pensky-Martens method according to ISO 2719.
The result is: 248.0°C
Executive summary:

The results of the main tests are:

 First determination:            Flash point, corrected for atmospheric pressure: 247.5°C

 Second determination:     Flash point, corrected for atmospheric pressure: 248.0°C

 

The results of the two tests were averaged and rounded off to the nearest 0.5°C to obtain the final flash point value:

 

Flash point Panthenyltriacetate: 248.0°C.