Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 August 2016 to 16 August 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
- Purity: 96.6%
- Description: yellow viscous liquid
Key result
Flash point:
135 °C
Atm. press.:
101.6 kPa
Conclusions:
Under the conditions of the study, the flash point of the test item has been determined to be 135 ± 2 °C.
Executive summary:

Under the conditions of the study, the flash point of the test item has been determined to be 135 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

Under the conditions of the study, the flash point of the test item has been determined to be 135 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
135 °C

Additional information