Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 06, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
impurity
Type:
impurity
Test material form:
liquid: viscous
Specific details on test material used for the study:
Lot No.: 1490443REC
Aspect: viscous liquid, may crystallise
Purity: 96.4% (GC-MS)

Results and discussion

Flash point
Flash point:
122 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: corrected to atmospheric pressure

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The results of the main tests are:

First determination: Flash point, corrected for atmospheric pressure: 123.0 ºC
Second determination: Flash point, corrected for atmospheric pressure: 122.0 ºC

The results of the two tests were averaged and round off to the nearest 0.5°C to obtain the final flash point value:

Flash point Hydroxy DHLL: 122.0 °C
Executive summary:

The flash point of Hydroxy DHLL was determined by the Pensky-Martens method according to ISO 2719/EU Method A.9.

The flash point is 122.0 °C