Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 212-266-7 | CAS number: 774-55-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 07 August 2017 - 14 August 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
- Version / remarks:
- 28 July 2015
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
- Version / remarks:
- 20 July 2012
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- dd 3 November 2015
- Specific details on test material used for the study:
- No correction factor for purity required.
Physical appearance: colourless to pale yellow liquid
Storage conditions: at room temperature protected from light, container flushed with nitrogen. - Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- skin obtained from plastic surgery from multiple donors
- Justification for test system used:
- In the interest of sound science and animal welfare, a sequential testing strategy is recommended to minimize the need of in vivo testing. One of the validated in vitro skin irritation tests is the EPISKIN test, which is recommended in international guidelines (e.g. OECD and EC).
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EPISKIN Small Model(TM)
- Tissue batch number(s): 17-EKIN-032
- Surface: 0.38 cm^2
- Expiration date: 14 August 2017
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: room temperature
- Temperature of post-treatment incubation (if applicable): 36.6 - 37.5°C
REMOVAL OF TEST MATERIAL AND CONTROLS
- Volume and number of washing steps: tissues were washed with PBS (1 washing step)
- Observable damage in the tissue due to washing: no
- Before the start of the study, the test item was checked for possible direct MTT reduction and color interference. It was concluded that the test item did not interfere with the MTT endpoint.
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE:
- Incubation time: 3 hours
- Measurement method: TECAN Infinite M200 Pro Plate Reader (570 nm)
- MTT concentration: 0.3 mg/mL
NUMBER OF REPLICATE TISSUES: 3 for the test substance, the negative and the positive control each.
NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: 1 single run
CELL VIABILITY MEASUREMENT: After incubation, tissues were dried and incubated with 2 mL MTT-solution for 3 hours. After incubation, epidermis was separated from the collagen matrix and both parts were extracted with 500 μL isopropanol. The amount of extracted formazan was determined spectrophotometrically at 570 nm in duplicate with the TECAN Infinite® M200 Pro Plate Reader.
PREDICTION MODEL / DECISION CRITERIA (see table 1 in 'Any other information on materials and methods')
A test item is considered irritant in the skin irritation test if:
The relative mean tissue viability of three individual tissues after 15 minutes of exposure to the test item and 42 hours of post incubation is ≤ 50% of the mean viability of the negative controls.
A test item is considered non-irritant in the in vitro skin irritation test if:
The relative mean tissue viability of three individual tissues after 15 minutes of exposure to the test item and 42 hours of post incubation is > 50% of the mean viability of the negative controls.
ACCEPTABILITY CRITERIA
a) The absolute mean OD570 (optical density at 570 nm) of the three tissues of the negative control should reasonably be within the laboratory historical control data range and the Standard Deviation value (SD) of the % viability should be ≤18.
b) The mean relative tissue viability of the positive control should be ≤50% relative to the negative control and the Standard Deviation value (SD) of the % viability should be ≤18.
c) The SD calculated from individual % tissue viabilities of the three identically treated replicates should be ≤18. - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- TEST MATERIAL
- Amount applied: 25 μL
NEGATIVE CONTROL
- Amount applied: 25 μL
POSITIVE CONTROL
- Amount applied: 25 μL, re-spread afer 7 minutes of contact time - Duration of treatment / exposure:
- 15 +/- 0.5 minutes
- Duration of post-treatment incubation (if applicable):
- 42 hours; + 3 hours with MTT
- Number of replicates:
- 3 for the test item, the negative control and the positive control each.
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Mean of 3 replicates
- Value:
- 12
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks:
- Mean tissue viability: 4.8%
- Other effects / acceptance of results:
- - OTHER EFFECTS:
- Visible damage on test system: no
- Direct-MTT reduction: no
- Colour interference with MTT: no
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes, the absolute mean OD570 of the negative control tissues was within the laboratory historical control data range and the SD of the % viability was 1.3%.
- Acceptance criteria met for positive control: yes, the mean relative tissue viability was 4.8% and the SD of the % viability was 2.3%
- Acceptance criteria met for variability between replicate measurements: yes, the standard deviation of the three tissue replicates treated with test substance was 6.3%.
- Since the mean relative tissue viability for the test item was below 50% the test item is considered to be irritant. - Interpretation of results:
- Category 2 (irritant) based on GHS criteria
- Remarks:
- Classified as Category 2 based on Regulation (EC) 1272/2008.
- Conclusions:
- In an in vitro skin irritation test, performed according to OECD guideline 439 and under GLP principles, Florantone T showed to be irritant with a tissue viability of 12% after 15 minutes of treatment. Based on these results, the substance is classified as Category 2 (irritant) according to GHS and Regulation (EC) 1272/2008.
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 19 Oct 2017 - 20 Oct 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- Chemical name (IUPAC, synonym or trade name: 1-(5,6,7,8-tetrahydro-2-naphthyl)ethan-1-one
CAS number: 774-55-0
Test item storage: At room temperature protected from light container flushed with nitrogen - Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- other: organized basal, spinous and granular layers, and a multi-layered stratum corneum containing intercellular lamellar lipid layers arranged in patterns
- Source strain:
- other: cultured tissues
- Justification for test system used:
- Recommended test system in international guidelines (OECD and EC)
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: human-derived epidermal keratinocytes
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: room temperature
REMOVAL OF TEST MATERIAL AND CONTROLS
- washed with phosphate buffered saline
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 300 μl MTT-medium
- Incubation time: 3 hours at 37°C
- Wavelength: 570 nm
NUMBER OF REPLICATE TISSUES: triplicate
PREDICTION MODEL / DECISION CRITERIA
- The test substance is considered to be corrosive to skin if the relative mean tissue viability obtained after 3-minute treatment compared to the negative control tissues is decreased below 50% a test item considered non-corrosive (viability ≥ 50%) after the 3-minute treatment is considered corrosive if the relative tissue viability after 1-hour treatment with the test item is decreased below 15%.
- The test substance is considered to be non-corrosive to skin if the relative mean tissue viability obtained after the 3-minute treatment compared to the negative control tissues is not decreased below 50%. In addition, the relative tissue viability after the 1-hour treatment is not decreased below 15%. - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- 50 μl of undiluted test item applied directly
- Duration of treatment / exposure:
- 3-minute exposure
1-hour exposure - Details on study design:
- Calculation of Cell Viability: The corrected OD (ODc) for each sample or control was calculated by subtracting the value of the blank mean (ODbl) from each reading (ODraw).
ODc = ODraw – ODbl
The OD value representing 100% cell viability is the average OD of the negative controls (ODlt_u+MTT).
The %Viability for each sample and positive control is calculated as follows: %Viability = (ODc/mean ODlt_u+MTT) * 100
number of replicates: triplicate - Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 3 minutes
- Value:
- 107
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 1-hour
- Value:
- 102
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Irritation / corrosion parameter:
- other: Mean Absorption
- Run / experiment:
- 3-minutes
- Value:
- >= 2.059 - <= 2.263
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Irritation / corrosion parameter:
- other: Mean Absorption
- Run / experiment:
- 1-hour
- Value:
- >= 2.247 - <= 2.377
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- The absolute mean OD570 (optical density at 570 nm) of the negative control tissues was within the acceptance limits of OECD 431 (lower acceptance limit ≥0.8 and upper acceptance limit ≤2.8) and the laboratory historical control data range. The mean relative tissue viability following the 1-hour exposure to the positive control was 7.7%.
In the range of 20 - 100% viability the Coefficient of Variation between tissue replicates was < 8%, indicating that the test system functioned properly. - Interpretation of results:
- study cannot be used for classification
- Remarks:
- The study cannot be used stand-alone to draw a conclusion on classification.
- Conclusions:
- In conclusion, the test substance is not corrosive in the in vitro skin corrosion test under the experimental conditions described in this report.
Referenceopen allclose all
Endpoint conclusion
- Endpoint conclusion:
- adverse effect observed (irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 02 August 2017 - 04 August 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- 28 July 2015
- Deviations:
- no
- GLP compliance:
- yes
- Specific details on test material used for the study:
- No correction factor for purity required.
- Species:
- human
- Details on test animals or tissues and environmental conditions:
- TEST SYSTEM:
The EpiOcular tissue construct is a nonkeratinized epithelium prepared from normal human keratinocytes. It models the cornea epithelium with progressively stratified, but not cornified cells. A cell suspension is seeded into the insert in specialized medium. After an initial period of submerged culture, the medium is removed from the top of the tissue so that the epithelial surface is in direct contact with the air. This allows the test material to be directly applied to the epithelial surface in a fashion similar to how the corneal epithelium would be exposed in vivo.
- Justification: In the interest of sound science and animal welfare, a sequential testing strategy is recommended to minimize the need of in vivo testing. One of the validated in vitro eye irritation tests is the EpiOcular test, which is recommended in international guidelines and scientific publications (e.g. OECD). - Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount applied: 50 μL
- The test material was directly applied to the tissues which were pre-wetted with 20 μL of Ca2+Mg2+-Free-DPBS.
POSITIVE CONTROL
- Amount applied: 50 μL Methyl Acetate
NEGATIVE CONTROL
- Amount applied: 50 μL Milli-Q water - Duration of treatment / exposure:
- 30 minutes ± 2 minutes
- Duration of post- treatment incubation (in vitro):
- Post-soak: 12 ± 2 minutes; incubation after the post-soak: 120 minutes ± 15 minutes
- Number of animals or in vitro replicates:
- 2 tissues per test item and 2 tissues for the negative and the positive control each.
- Details on study design:
- - Details of the test procedure used:
- RhCE tissue construct used, including batch number: EpiOcular™ (OCL-200-EIT MatTek Corporation, Lot: 23491)
- Duration and temperature:
Before the assay was started the entire tissues were pre-wetted with 20 μL of Ca2+Mg2+-Free-DPBS and incubated at standard culture conditions for 30 ± 2 minutes.
* exposure: 30 minutes ± 2 minutes at 37.0 ± 1.0°C
After the exposure period, the tissues were thoroughly rinsed with Ca2+Mg2+-free DPBS (brought to room temperature) to remove residual test item.
* post-soak immersion: 12 ± 2 minutes at room temperature in assay medium
* incubation: 120 minutes ± 15 minutes at 37°C in assay medium + 180 ± 10 minutes with MTT
- The test item was checked for possible color interference and possible direct MTT reduction before the study was started.
- Cell viability measurements:
After incubation, the tissues were incubated with 0.3 mL MTT-medium (1.0 mg/ml) for 180 ± 10 minutes at 37°C. After incubation with MTT-medium the tissues were transferred to a 6-well plate containing 2 mL isopropanol. Formazan was extracted with 2 mL isopropanol for 2 - 3 hours at room temperature with gentle shaking. The amount of extracted formazan was determined spectrophotometrically at 570 nm in duplicate with the TECAN Infinite® M200 Pro Plate Reader. Cell viability was calculated for each tissue as a percentage of the mean of the negative control tissues. Eye hazard potential of the test item was classified according to remaining cell viability following exposure of the test item.
- Evaluation criteria:
* The test chemical is identified as not requiring classification and labelling according to UN GHS (No Category) if the mean percent tissue viability after exposure and post-exposure incubation is more than (>) 60%. In this case no further testing in other test methods is required.
* The test chemical is identified as potentially requiring classification and labelling according to UN GHS (Category 2 or Category 1) if the mean percent tissue viability after exposure and post-exposure incubation is less than or equal (≤) to 60%.
- Acceptability criteria:
* The absolute mean OD570 of the two tissues of the negative control should reasonably be > 0.8 and < 2.5.
* The mean relative tissue viability of the positive control should be <50% relative to the negative control.
* The difference between the % tissue viabilities of the two identically treated replicates should be <20%. - Irritation parameter:
- other: Mean cell viability (%)
- Value:
- 78
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks:
- Mean tissue viability: 36%
- Remarks on result:
- other: SD: 6.6%
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: no
DEMONSTRATION OF TECHNICAL PROFICIENCY: see 'any other information on results' for historical data. Results for the positive control were within the historical data range and therefore showing that the test system was functioning properly.
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes, the absolute mean OD570 of the two tissues of the negative control was between >0.8 and <2.5 (i.e., 2.005)
- Acceptance criteria met for positive control: yes, the mean relative tissue viability of the positive control was <50% (i.e., 36%)
- The difference between the % tissue viabilities of the two identically treated replicates was <20% (i.e., 2.9, 6.6 and 2.1 for the negative control, the treatment group and the positive control respectively) - Interpretation of results:
- GHS criteria not met
- Remarks:
- Not classified according to Regulation (EC) No. 1272/2008
- Conclusions:
- In an in vitro skin corrosion EpiOcular test, Florantone T was not irritant or corrosive to the eyes with a mean cell viability of 78% compared to the negative control. Based on these results, the test item is not classified according to GHS and according to Regulation (EC) No. 1272/2008.
Reference
Table 1 Historical data for EpiOcular studies
|
Negative control (absorption; OD570) |
Positive control (absorption; OD570) |
Positive control (viability; %) |
Range |
1.077 – 1.805 |
0.029 – 0.793 |
2.11 – 48.25 |
Mean |
1.52 |
0.42 |
26.86 |
SD |
0.21 |
0.23 |
14.11 |
n |
16 |
16 |
16 |
SD = Standard deviation
n = Number of observations
The above mentioned historical control data range of the controls were obtained by collecting all data over the period of January 2013 to May 2017.
Table 2 Individual OD570 measurements
|
A (OD570) |
B (OD570) |
Negative control OD570 measurement 1 OD570 measurement 2 |
2.0133 1.9993 |
2.0902 2.0852 |
FLORANTONE T OD570 measurement 1 OD570 measurement 2 |
1.7194 1.6748 |
1.5154 1.5050 |
Positive control OD570 measurement 1 OD570 measurement 2 |
0.7296 0.7209 |
0.7955 0.7726 |
OD = Optical density
Duplicate exposures are indicated by A and B.
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Justification for classification or non-classification
Skin irritation/ corrosion
Two in vivo studies were available, one conducted in 1985 with 5% of the substance on Albino rabbits, and the other conducted in 1984 on Guinea pigs at up to 50% of the substance.
Neither study was considered sufficently reliable to conclude on the endpoint.
Two in vitro studies based on the Reconstructed Human Epidermis model were used for this endpoint:
A first irritation test was conducted on Reconstituted Human Epidermis (OECD 439), the relative mean tissue viability was 12% Therefore, as it was not possible to conclude on the skin irritation or skin corrosion potential (cat. 2 or cat. 1), a second in vitro corrosion stuudy was conducted.
The corrosion test was conducted with EpiDerm (OECD 431), the 3 -min and the 1 -hr treatments gave respectively a relative mean viability of 107% and 102%.
Therefore, the test item is not a skin corrosive but it has to be claissified as a skin irritant cat. 2 (according to GHS & EU CLP).
Eye irritation/ corrosion
An in vitro irritation test was conducted with EpiOcular (OECD 492) and relative mean tissue viability was 78%.
It was concluded that the substance does not have to be classified as an eye irritant or corrosive.
Therefore for this endpoint it classified as "No category" (according to GHS & EU CLP).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.