Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
not specified
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
Not specified
Specific details on test material used for the study:
Material: Solvent-free Dabco TMR-2
Color: Clear
Physical State: Liquid
Date Received: 08/11/2016
Key result
Flash point:
155.5 °C
Atm. press.:
993 mBar
Flash point:
157.5 °C
Atm. press.:
993 mBar
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flashpoint of Solvent-free Dabco TMR-2 was measured as 155.5 ± 1°C

Description of key information

The flashpoint of Solvent-free Dabco TMR-2 was measured as 155.5 ± 1°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
155.5 °C

Additional information