Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
yes
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
Identification: 2-ethylhexyl 7-oxabicyclo[4.1.0]heptane-3-carboxylate
Appearance/Physical state: Clear colourless liquid
Batch: AH03201
Purity: 99.47%
Expiry date: 01 February 2019
Storage conditions: Approximately 4 °C, in the dark
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
14.9
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
7.39
Conclusions:
The viscosity at 20 ºC was 14. 9 mm2/s and at 40 ºC was 7.39 mm2/s.
Executive summary:

The viscosity of the test item was determined using a capillary viscometer method, designed to be compatible with Method 114 of the OECD Guidelines for Testing of Chemicals, 02 October 2012. The viscosity at 20 ºC was 14. 9 mm2/s and at 40 ºC was 7.39 mm2/s.

Description of key information

Key value for chemical safety assessment

Viscosity:
14.9 mm²/s (static)
at the temperature of:
20 °C

Additional information

The viscosity at 20 ºC was 14. 9 mm2/s and at 40 ºC was 7.39 mm2/s.