Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
Appearance/Physical state: Clear colorless liquid
Batch: AH03201
Purity: 100%
Expiry date: 01 February 2019
Storage conditions: Approximately 4 °C in the dark

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
250 °C
Atm. press.:
101 kPa

Applicant's summary and conclusion

Conclusions:
The test item has been determined to have an auto-ignition temperature of 250 ± 5 °C.
Executive summary:

The determination was carried out using a procedure designed to be compatible with Method A.15 Auto-Ignition Temperature (Liquids and Gases) of Commission Regulation (EC) No 440/2008 of 30 May 2008. The test flask was heated in a flask heater. Aliquots of test item (tested as received) were injected into the flask using a syringe and the flask was observed for signs of ignition over a 300 second period. This procedure was repeated, varying the sample size, as necessary, until the lowest temperature at which ignition, if any, occurred within 300 seconds of insertion, was determined. Where clean flasks were not used, the flask was flushed with air between sample insertions. The test item has been determined to have an auto-ignition temperature of 250 ± 5 °C.