Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-08-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Specific details on test material used for the study:
Batch No.: FK650468
Purity: 100%
Percentile:
D10
Mean:
12.15 µm
St. dev.:
0.36
Percentile:
D50
Mean:
138.2 µm
St. dev.:
4.85
Percentile:
D90
Mean:
286.9 µm
St. dev.:
8.9

Particle Size Distribution Test Results:

Test item

Test Times

Average (µm)

SD

RSD%

1

2

3

D50 (µm)

142.9

138.4

133.2

138.2

4.85

3.5

D10 (µm)

12.39

12.32

11.74

12.15

0.36

2.9

D90 (µm)

295.7

287.2

277.9

286.9

8.90

3.1

Conclusions:
The average of D50 was 138.2 µm and the RSD% was 2.9% (n=3); the average of D10 was 12.15 µm and the RSD% was 3.5% (n=3); the average of D90 was 286.9 µm and the RSD% was 3.1% (n=3).
Executive summary:

The particle size distribution of test item was tested for three times from preparing test suspension under the same conditions according to OECD 110. Based on the testing results, the average of D50was138.2 µm and the RSD% was 2.9% (n=3); the average of D10was 12.15 µm and the RSD% was 3.5% (n=3); the average of D90was 286.9 µm and the RSD% was 3.1% (n=3).

Description of key information

The average of D50was138.2 µm and the RSD% was 2.9% (n=3); the average of D10was 12.15 µm and the RSD% was 3.5% (n=3); the average of D90was 286.9 µm and the RSD% was 3.1% (n=3).

Additional information