Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Principles of method if other than guideline:
A sample of Dodecenyl succinic acid, compound with 2,2',2''-nitrilotriethanol was placed into the sample cup up to the fill line. The sample was then run on the Pensky-martens closed cup machine to determine the lowest temperature at which the sample can form an ignitable mixture in the air.
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Details on test material:
Commercial grade containing approximately 45% actives
Specific details on test material used for the study:
Batch #KB1704098

Results and discussion

Flash point
Flash point:
> 85 °C
Atm. press.:
ca. 1 atm
Remarks on result:
no flash point according to standard method

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Considered non-flammable.