Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
effusion method: Knudsen cell
Key result
Test no.:
#9
Temp.:
ca. 150 °C
Vapour pressure:
0.015 Pa

Calculation Results Experiment 9

Experiment

9

 

 

 

 

 

 

 

 

Real Temperature in K

423.2

 

 

 

 

 

 

 

 

Real Temperature in °C

150.0

 

 

 

 

 

 

 

 

Date of Measurement

29.06.2017 11:45

30.06.2017 11:30

04.07.2017 12:00

Elapsed Time in s

82200

82500

91800

Parameter

Weight loss

to be used

Vapour pressure

Weight loss

to be used

Vapour pressure

Weight loss

to be used

Vapour pressure

Unit

g

yes/no

Pa

g

yes/no

Pa

g

yes/no

Pa

Knudsen-cell 1

0.00009

yes

2.65E-04

0.00000

yes

0.00E+00

0.00544

yes

1.44E-02

Knudsen-cell 2

0.00010

yes

2.95E-04

0.00000

yes

0.00E+00

0.00522

yes

1.38E-02

Knudsen-cell 3

-0.00007

yes

-2.06E-04

0.00000

yes

0.00E+00

0.00571

yes

1.51E-02

Knudsen-cell 4

-0.00001

yes

-2.95E-05

0.00000

yes

0.00E+00

0.00593

yes

1.57E-02

Mean

 

yes

8.11E-05

 

yes

0.00E+00

 

yes

1.47E-02

Standard deviation:

 

 

2.41E-04

 

 

0.00E+00

 

 

8.19E-04

Mean of measured values:

 

4.933E-03

 

 

 

 

 

 

Standard deviation:

 

8.473E-03

RSD:

171.8%

 

 

 

 

 Vapour pressure was examined at nine different temperatures. No temperatures could be evaluated as they showed no reproducible or relevant weight loss.

As a calculation on base of the measured weight losses is not possible, the highest vapour pressure, derived from all measurements, is stated as limit value. At the first measurement of experiment 1 (30 °C) impurities like water can yield a higher vapour pressure, therefore these measurements were not taken into account.

 

Vapour pressure at 150 °C:        1.47* 10-02Pa

Conclusions:
Vapour pressure at 150 °C:        1.47* 10-02Pa
Executive summary:

1      Results

Vapour pressure was examined at nine different temperatures. No temperatures could be evaluated as they showed no reproducible or relevant weight loss.

As a calculation on base of the measured weight losses is not possible, the highest vapour pressure, derived from all measurements, is stated as limit value. At the first measurement of experiment 1 (30 °C) impurities like water can yield a higher vapour pressure, therefore these measurements were not taken into account.

 

Vapour pressure at 150 °C:        1.47* 10-02Pa

Description of key information

Calculation Results Experiment 9

Experiment

9

 

 

 

 

 

 

 

 

Real Temperature in K

423.2

 

 

 

 

 

 

 

 

Real Temperature in °C

150.0

 

 

 

 

 

 

 

 

Date of Measurement

29.06.2017 11:45

30.06.2017 11:30

04.07.2017 12:00

Elapsed Time in s

82200

82500

91800

Parameter

Weight loss

to be used

Vapour pressure

Weight loss

to be used

Vapour pressure

Weight loss

to be used

Vapour pressure

Unit

g

yes/no

Pa

g

yes/no

Pa

g

yes/no

Pa

Knudsen-cell 1

0.00009

yes

2.65E-04

0.00000

yes

0.00E+00

0.00544

yes

1.44E-02

Knudsen-cell 2

0.00010

yes

2.95E-04

0.00000

yes

0.00E+00

0.00522

yes

1.38E-02

Knudsen-cell 3

-0.00007

yes

-2.06E-04

0.00000

yes

0.00E+00

0.00571

yes

1.51E-02

Knudsen-cell 4

-0.00001

yes

-2.95E-05

0.00000

yes

0.00E+00

0.00593

yes

1.57E-02

Mean

 

yes

8.11E-05

 

yes

0.00E+00

 

yes

1.47E-02

Standard deviation:

 

 

2.41E-04

 

 

0.00E+00

 

 

8.19E-04

Mean of measured values:

 

4.933E-03

 

 

 

 

 

 

Standard deviation:

 

8.473E-03

RSD:

171.8%

 

 

 

 

 

Key value for chemical safety assessment

Vapour pressure:
0.015 Pa
at the temperature of:
150 °C

Additional information

Results

Vapour pressure was examined at nine different temperatures. No temperatures could be evaluated as they showed no reproducible or relevant weight loss.

As a calculation on base of the measured weight losses is not possible, the highest vapour pressure, derived from all measurements, is stated as limit value. At the first measurement of experiment 1 (30 °C) impurities like water can yield a higher vapour pressure, therefore these measurements were not taken into account.

 

Vapour pressure at 150 °C:        1.47* 10-02Pa