Registration Dossier

Administrative data

Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-08-04 (experimental phase)
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Remarks:
in-house data with poorer documentation, but given data allows to conclude that the study was properly conducted

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
not specified
Type of method:
oscillating densitimeter

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Density
Key result
Type:
density
Density:
1.11 other: dimensionless
Temp.:
25 °C

Applicant's summary and conclusion

Conclusions:
The study was performed according to OECD 109 using an Oscillating densitometer (liquids). Tests done with the Stabinger viscometer comply with the following standards: Density (EN ISO 12185, ASTM D4052, IP 365). The study was performed on the substance to be registered itself, the test procedure is sufficiently documented and therefore reliability of Klimisch 2 has been assigned. Density was determined to be 1.1103 at 25 °C.
Executive summary:

The density was determined in an OECD 109 study using an Oscillating densitometer (liquids) to be 1.1103 at 25 °C.