Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29.11.2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
no
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Boiling point
Boiling pt.:
> 345 - < 357 °C
Atm. press.:
1 013.3 hPa
Decomposition:
yes

Applicant's summary and conclusion

Executive summary:

The lest item has a boiling range between 345 °C and 357 °C under atmospheric conditions.