Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03 June 2016 to 06 July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
143 °C
Remarks on result:
other: result was corrected for atmospheric pressure

TABLE 1 – RESULTS OF FLASH POINT DETERMINATION

Test temperature (°C)

Observations

21.0

No flash

26.0

No flash

31.0

No flash

36.0

No flash

41.0

No flash

46.0

No flash

51.0

No flash

56.0

No flash

61.0

No flash

66.0

No flash

71.0

No flash

71.0 (fresh sample)

No flash

76.0

No flash

81.0

No flash

86.0

No flash

91.0

No flash

96.0

No flash

101.0 (fresh sample)

No flash

106.0

No flash

111.0

No flash

116.0

No flash

121.0

No flash

126.0

No flash

131.0

No flash

136.0

No flash

141.0

No flash

146.0

A blue flash spread across the sample cup

146.0 (fresh sample)

A blue flash spread across the sample cup

141.0 (fresh sample)

No flash

142.0 (fresh sample)

No flash

143.0 (fresh sample)

A blue flash spread across the sample cup

143.0 (fresh sample)

A blue flash spread across the sample cup

141.0 (fresh sample)

No flash

Atmospheric pressure: 101.6 kPa

Corrected flash point: 142.9 °C

Interpretation of results:
GHS criteria not met
Conclusions:
The flashpoint of the test item was determined to be 143 ± 2 °C.
Executive summary:

GUIDELINE

The determination was carried out using a closed cup Setaflash 30000-0 flash point tester and was designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

RESULTS

The flashpoint of the test item was determined to be 143 ± 2 °C.

Description of key information

The flashpoint of the test item was determined to be 143 ± 2 °C (EU Method A.9).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
143 °C

Additional information

GUIDELINE

The determination was carried out using a closed cup Setaflash 30000-0 flash point tester and was designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

RESULTS

The flashpoint of the test item was determined to be 143 ± 2 °C.