Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 June 2017 - 02 November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Constituent 1
Reference substance name:
trichloropraseodymium; heptahydrate
Cas Number:
10025-90-8
Molecular formula:
PrCl3.7H2O
IUPAC Name:
trichloropraseodymium; heptahydrate
Test material form:
solid: particulate/powder
Details on test material:
- Name of the test material (as in the report): praseodymium trichloride heptahydrate
- Physical state: solid
- Appearance: green crystalline powder
- Further information on test material confidential.

Results and discussion

Density
Key result
Type:
relative density
Density:
ca. 2.233
Temp.:
19.6 °C
Remarks on result:
other: Mean value of two assays (assay No.1: 2.242 ± 0.002 , assay No.2: 2.224 ± 0.001).

Any other information on results incl. tables

Two independent measurements at 19.2°C (assay No. 1) and 20°C (assay No. 2) were done. Run 1 of assay No. 1 and runs 1, 2, 3, 4 and 5 of assay No. 2 were not taken into account because they did not comply with the quality criterion. A longer stabilisation time of the pressure was needed to obtain three consequent runs complying with the quality criterion.

The two assays resulted in relative densities of 2.242 ± 0.002 and 2.224 ± 0.001, respectively. The mean relative density was thus 2.233 ± 0.010 at 19.6°C.

Reference volume (Va) was 79.444 cm³.

Volume of sample cell holder (Vc) was 27.678 cm³.

Test item sample weight was 7.5900 g and 8.0786 g in assay No. 1 and 2, respectively.

The measurements are described in the table in the next section.

Applicant's summary and conclusion

Conclusions:
The relative density of praseodymium trichloride heptahydrate was determined according to EU A.3 method and OECD test guideline 109 in compliance with GLP using a gas comparison pycnometer. The relative density of the test item was determined to be 2.233 ± 0.010 at 19.6°C.