Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study starting date 2017-09-15; Experimental starting date 2017-09-20; Experimental completion date 2017-09-20
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Source: ExxonMobil Research and Engineering (Paulsborro, NJ)
Lot: 17-064163-4
- Expiration date of the lot/batch: 20 March 2019
-Purity test date: 25 September 2017
Appearance: Light grey powder
Storage conditions: Room temperature, keep container tightly closed
Key result
Percentile:
D10
Mean:
18.5 µm
St. dev.:
0.07
Key result
Percentile:
D50
Mean:
324.2 µm
St. dev.:
3.5
Key result
Percentile:
D75
Mean:
978.4 µm
St. dev.:
2.3

Test series 1:

D10:       18.5 µm

D50:       321.7 µm        (Median diameter)

D90:       980.0 µm

Test series 2:

D10:       18.6 µm

D50:       326.7 µm        (Median diameter)

D90:       976.7 µm

Executive summary:

The test item Lithium salicylate has a volume median diameter (VMD) of D50 = 324.2 µm, which was determined by laser diffraction measurement according to ISO 13320 (2009) and OECD Guideline 110 (1981).

Description of key information

The test item Lithium salicylate has a volume median diameter (VMD) ofD50 = 324.2 µm, which was determined by laser diffraction measurement according to ISO 13320 (2009) and OECD Guideline 110 (1981).

Additional information