Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
corresponds to Method A of DIN EN ISO 2719
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
131 °C
Atm. press.:
101.3 kPa
Conclusions:
The flash point of the test item is 131 ± 2 °C.
Executive summary:

The flash point of the test substance was determined in a guideline study according to EU method DIN EN ISO 2719

The flash point of the test itemis 131 +/- 2 °C at 101.3 kPa.

Description of key information

Flash point of the test material: 131 ± 2 °C (corr. to DIN EN ISO 2719)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
131 °C

Additional information