Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5 January 2005 - 3 February 2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Appearance: Clear, colourless liquid
Storage conditions: Room temperature in the dark
Batch number: 52834
Expiry date: December 2005
Purity: > 98%
Key result
Flash point:
103 °C
Atm. press.:
1 035 mBar
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test substance was found to be 103°C.

Description of key information

The flash point of the test substance was found to be 103°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
103 °C

Additional information