Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21.11.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
yes (incl. QA statement)
Remarks:
consilab, Gesellschaft für Anlagensicherheit mbH, Industriepark Höchst, G830/G840, 65926 Frankfurt am Main (Germany)

Test material

Constituent 1
Reference substance name:
L-Threonine, N-coco acyl derivs., monosodium salts
Cas Number:
90583-79-2
Molecular formula:
n/a
IUPAC Name:
L-Threonine, N-coco acyl derivs., monosodium salts
Test material form:
solid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Ajinomoto Co., Inc., 15-1, Kyobashi 1-chome, Chuo-ku, Tokyo 104-8315, Japan, Batch No.: 160329
- Expiration date of the lot/batch: 2019-03-29
- Purity test date: 2016-06-09

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: stored at ambient temperature

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
In the preliminary test, the test item could not be ignited by a flame and therefore the performance of the main test was not necessary. Based on the result, the test item has not to be classified as a readily combustible solid according to UN Transport Regulation nor as a flammable solid according to CLP Regulation EC 1272/2008.
Executive summary:

The flammability of the test item was investigated in a study conducted according to UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids). In the preliminary test, the test item could not be ignited by a flame. Thus, the performance of the main test was not necessary. Based on the result, the test item has not to be classified as a readily combustible solid according to UN Transport Regulation nor as a flammable solid according to CLP Regulation EC 1272/2008.