Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Non flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

According to the CLP Regulation (EC n.1272/2008) flammable liquid means a liquid having a flash point of not more than 60 °C.  The experimental flash-point of the substance was determined on a manual Pensky-Martens closed-cup apparatus according to ASTM D93 method and it is > 200 °C. The test item doesn't satisfy the CLP Regulation (EC n.1272/2008) requirement for flammable liquid, so no further tests and no classification as flammable liquid are suggested.

Justification for classification or non-classification

Considering its flash point higher than 200 °C, the substance is not classified as flammable liquid according to the CLP Regulation (EC n.1272/2008).