Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11.04.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
consilab Gesellschaft für Anlagensicherheit mbH, Industriepark Höchst, G830/G840, 65926 Frankfurt am Main (Germany)

Test material

Constituent 1
Chemical structure
Reference substance name:
Glycine, N-coco acyl derivs., sodium salts
EC Number:
291-350-5
EC Name:
Glycine, N-coco acyl derivs., sodium salts
Cas Number:
90387-74-9
Molecular formula:
Molecular formula for this UVCB is not available.
IUPAC Name:
Glycine, N-coco acyl derivs., sodium salts
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Ajinomoto Co., Inc., 15-1, Kyobashi 1-chome, Chuo-ku, Tokyo, 104-8315, Japan
- Expiration date of the lot/batch: 03.10.2019
- Purity test date: 15.11.2016

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature


TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: no

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
other: not readily combustible solid (acc. to UN Transport Regulation) and not flammable solid (acc. to GHS)
Conclusions:
The test item has to be classified as a not readily combustible and not flammable solid.
Executive summary:

The flammability of the test item was investigated according to UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids). In the preliminary screening test, the test item could be ignited at room temperature with a flame as ignition source. Within 2 minutes, the test item burned locally over 10 mm but could not be ignited by the flame. Based on this result, the main test had not to be performed. In consequence of the observations, the test item has not to be classified as a readily combustible solid (acc. to UN Transport Regulation) and flammable solid (acc. to GHS).