Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27.02.2018 to 08.03.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: UN Recommendations on the Transport of Dangerous Goods: Manual of Tests and Criteria, Rev. 6 (2015) and UN-Model Regulations, Rev. 20 (2017)
GLP compliance:
yes (incl. QA statement)
Remarks:
consilab Gesellschaft für Anlagensicherheit mbH, Industriepark Höchst, G830/G840, 65926 Frankfurt am Main (Germany)

Test material

Constituent 1
Chemical structure
Reference substance name:
Glycine, N-coco acyl derivs., sodium salts
EC Number:
291-350-5
EC Name:
Glycine, N-coco acyl derivs., sodium salts
Cas Number:
90387-74-9
Molecular formula:
Molecular formula for this UVCB is not available.
IUPAC Name:
Glycine, N-coco acyl derivs., sodium salts
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Ajinomoto Co., Inc., 15-1, Kyobashi 1-chome, Chuo-ku, Tokyo 104-8315, Japan, Batch No.: 161003
- Expiration date of the lot/batch: 03.10.2019
- Purity test date: 15.11.2016

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: no

Results and discussion

Relative self-ignition temperature (solids)
Key result
Remarks on result:
other: The test in the 1 L wire basket at 140 °C showed a self-heating of the test item with a temperature increase of < 60 K within 24 hours.

Applicant's summary and conclusion

Conclusions:
According to the results of the tests on the self-heating in the Bowes-Cameron-Cage Test (UN-Test N.4) the test item is classified as follows:
UN Transport Regulation: The test item has not to be classified as self-heating substance in Class 4, Division 4.2.
GHS (CLP Regulation EC 1272/2008 Annex 1: 2.11): The test item has not to be classified as self-heating substance.
Executive summary:

The self-ignition temperature of the test item was investigated in the Bowes-Cameron-Cage Test. In this test,a self-heating of the test item was observed as demonstrated by a measured temperature increase in the 1 L wire basket of < 60 K within 24 h of exposure at 140° C.

According to the results of the tests on the self-heating in the Bowes-Cameron-Cage Test (UN-Test N.4) the test item has to be classified as follows:

UN Transport Regulation: The test item has not to be classified as self-heating substance in Class 4, Division 4.2.

GHS (CLP Regulation EC 1272/2008 Annex 1: 2.11): The test item has not to be classified as self-heating substance.