Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 18, 2002
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Version / remarks:
adopted on 4 April 1984
Principles of method if other than guideline:
The study described in this report was conducted in accordance with ISO/IEC 17025.
GLP compliance:
not specified
Analytical monitoring:
no
Details on test solutions:
These test concentrations were prepared by direct addition of the test substance.
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Inoculum: activated sludge from the aeration tank of a municipal biological waste water treatment plant, not adapted, not pre-conditioned.
- Source: ARA Werdhölzli, CH-8048Zürich (18 September 2002;9.30 a.m.).
- Concentration: 1.6 g/l dry matter in the final mixture.
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Nominal and measured concentrations:
125, 250, 500, 1000 and 2000 mg/l nominal
Details on test conditions:
TEST SYSTEM
- Test vessel: 1000 ml flasks containing a total volume of test suspension of 500 ml.
- Aeration: aerated by shaking (120 r.p.m.).
- No. of vessels per concentration: one replicate.
- No. of vessels per control: 2 replicates.

TEST MEDIUM / WATER PARAMETERS
- Source of dilution water: synthetic sewage feed prepared with tap water.16 ml of 100-fold sewage concentrate per 500 ml of final test mixture.

EFFECT PARAMETERS MEASURED
The oxygen concentration, in mg/|, was measured with a oxygen electrode inserted to a 300 ml BOD bottle and recorded for about 5 to 10 min.
Reference substance (positive control):
yes
Remarks:
3,S-dichlorophenol
Duration:
3 h
Dose descriptor:
IC50
Effect conc.:
> 2 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
At the applied test concentrations, the following toxic effects to the activated sludge were observed: 2000 mg/l (45 %), 1000 mg/l (41 %), 500 mg/l (34 %), 250 mg/l (31 %),125 mg/(25 %).
Based on these data the EC20 value of test item was estimated to be lower than 125 mg/l. The EC50 and EC80 values were estimated to be higher than 2000 mg/l.

The variation between the two controls was ± 2.8 %.
Results with reference substance (positive control):
The EC50 value of the reference substance 3,5-dichlorophenol was estimated to be 2.5 mg/ which was low but in the range of 5 mg/l thus confirming suitability of activated sludge and test conditions.

Definitive test: activated sludge respiration rates after 3 h of exposure to the test material and calculation of the inhibition.

Nominal concentration (mg/l) O2 consumption rates (mg/O2l/h) Respiration inhibition (%)
Control 23.8 -
Control 25.2 -
Test item 125 18.3 25.1
Test item 250 16.9 30.9
Test item 500 16.2 33.8
Test item 1000 14.5 40.8
Test item 2000 13.4 45.2
Reference 3 11.5 53.1
Reference 10 7.0 71.4
Reference 30 2.7 88.9
Validity criteria fulfilled:
yes
Remarks:
The variation between the two controls was ± 2.8 % and the EC50 of reference substance was 2.5 mg/l
Conclusions:
IC50 (3h) > 2000 mg/l
Executive summary:

The inhibitory effect of test item on the oxygen consumption of activated sludge microorganisms of a municipal sewage treatment plant was investigated under aerobic static conditions. The inhibitory effect may include the effect on respiration and nitrification. The exposure time of the test substance on the activated sludge was 3 hours.

The nominal concentrations of test item were 125, 250, 500, 1000 and 2000 mg/l, respectively. These test concentrations were prepared by direct addition of the test substance. No chemical analysis of test concentrations was conducted. For the calculation of the effective concentration leading to 20, 50, and 80 % respiration inhibition the nominal content of the test substance was used, assuming the test compound to be stable in water over 3 h.

At the applied test concentrations, the following toxic effects to the activated sludge were observed: 2000 mg/l (45 %), 1000 mg/l (41 %), 500 mg/l (34 %), 250 mg/l (31 %),125 mg/(25 %).

Based on these data the EC20 value of test item was estimated to be lower than 125 mg/l. The EC50 and EC80 values were estimated to be higher than 2000 mg/l.

Conclusion

IC50 (3h) > 2000 mg/l

Description of key information

IC50 (3h) > 2000 mg/l

Key value for chemical safety assessment

Additional information

The inhibitory effect of test item on the oxygen consumption of activated sludge microorganisms of a municipal sewage treatment plant was investigated under aerobic static conditions. The nominal concentrations of test item were 125, 250, 500, 1000 and 2000 mg/l.

At the applied test concentrations, the following toxic effects to the activated sludge were observed: 2000 mg/l (45 %), 1000 mg/l (41 %), 500 mg/l (34 %), 250 mg/l (31 %),125 mg/(25 %). Based on these data the EC20 value of test item was estimated to be lower than 125 mg/l. The EC50 and EC80 values were estimated to be higher than 2000 mg/l.