Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 947-318-4 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Skin irritation / corrosion
Administrative data
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 13 February 2017 - 17 February 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 017
- Report date:
- 2017
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Version / remarks:
- 29 July 2016
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: EU method B.40 BIS (In Vitro Skin corrosion: Human Skin Model Test)
- Version / remarks:
- 31 May 2008
- Deviations:
- no
- GLP compliance:
- yes
Test material
- Reference substance name:
- Potassium hydrogen 2-octadecenylsuccinate
- EC Number:
- 296-086-4
- EC Name:
- Potassium hydrogen 2-octadecenylsuccinate
- Cas Number:
- 92218-39-8
- Molecular formula:
- C22H40O4.K
- IUPAC Name:
- hydrogen potassium 2-octadec-1-en-1-ylsuccinate
- Test material form:
- solid
- Details on test material:
- Name as cited in report: X-19924
Appearance: thick amber paste
Storage: at room temperature
Constituent 1
- Specific details on test material used for the study:
- Purity correction factor: 1.14
Stability at higher temperatures: stable at a maximum temperature of 60°C for a maximum duration of 30 minutes
In vitro test system
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- skin obtained from plastic surgery from multiple donors
- Details on animal used as source of test system:
- EpiDerm™ Reconstructed Human Epidermis (Lot no.: 24982 kit H and I)
- All cells used to produce Eipderm™ are purchased or derived from tissue obtained by MatTek Corporation from acredited institutions.
- Cells are screened for potential biological contaminants (HIV-1, Hepatitis B, Hepatitis C, bacteria, yeast and fungi) - Justification for test system used:
- Recommended test system in international guidelines (OECD and EC).
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm Skin Model (EPI-200)
- Tissue lot number: 24982 kit H and I
- Surface: 0.6 cm^2
- The model consists of keratinocytes which have been cultured to form a multilayered, highly differentiated model of the human epidermis.
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: All incubations, with the exception of the test item incubation of 3 minutes at room temperature, were carried out in a controlled environment at 37.0 ± 1.0°C (actual range: 36.6 - 37.0°C)
REMOVAL OF TEST MATERIAL AND CONTROLS
- After the exposure period, the tissues were washed with phosphate buffered saline to remove residual test item.
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1 mg/mL
- Incubation time: 3 h
- Spectrophotometer: TECAN Infinite® M200 Pro Plate Reader
- Wavelength: 570 nm
NUMBER OF REPLICATE TISSUES: 2 replicates per exposure duration (4 replicates per test item), one negative control, one positive contol.
ACCEPTANCE OF RESULTS:
The in vitro skin corrosion test is considered acceptable if it meets the following criteria:
a) The absolute mean OD570 of the two tissues of the negative control should reasonably be within the acceptance limits of OECD 431 (lower limite ≥0.8 and upper limit ≤2.8)
b) The mean relative tissue viability following 1-hour exposue to the positive control should be <15%
c) In the range 20-100% viability, the Coefficient of Variation (CV) between tissue replicates should be ≤30%.
DECISION CRITERIA: see table 1 - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- yes, concurrent MTT non-specific colour control
- other: concurrent control for MTT reduction by test item
- Amount/concentration applied:
- Excess amount of the paste, spread directly on top of skin moistened with 25 µL Milli-Q water
- Duration of treatment / exposure:
- 3-minute and 1-hour
- Duration of post-treatment incubation (if applicable):
- none
Results and discussion
In vitro
Resultsopen allclose all
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 3-minute exposure
- Value:
- 107
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Remarks:
- (100%)
- Positive controls validity:
- valid
- Remarks:
- (29%)
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 1-hour exposure
- Value:
- 90
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Remarks:
- (100%)
- Positive controls validity:
- valid
- Remarks:
- (9%)
- Other effects / acceptance of results:
- - Because the mean relative tissue viability for the test item was not below 50% after 3 minutes treatment and not below 15% after 1 hour treatment, the test item is considered to be non corrosive.
- OTHER EFFECTS:
- Direct-MTT reduction: No
- Colour interference with MTT: No
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: Yes
- Acceptance criteria met for positive control: Yes, mean relative tissue viability following 1-hour exposure was 9%.
- In the range of 20 - 100% viability the Coefficient of Variation between tissue replicates was ≤12% for the test item and negative control. For the positive control, the Coefficient of Variation between tissue replicates at the 3-minute exposure was 39%. Since both individual tissues of the positive control were clearly positive it was concluded that the test system functioned properly.
Table 2 shows the results of individual OD measurements at 570 nm.
Any other information on results incl. tables
Table 2 Individual OD measurements at 570 nm.
|
3-minute application (OD570) |
1-hour application (OD570) |
||
|
A |
B |
A |
B |
Negative control Measurement 1 Measurement 2 Measurement 3 |
1.4908 1.4052 1.4427 |
1.4308 1.3742 1.4020 |
1.7312 1.7305 1.6864 |
1.5932 1.5681 1.5657 |
X-19924 Measurement 1 Measurement 2 Measurement 3 |
1.6368 1.6057 1.5798 |
1.4898 1.3770 1.4145 |
1.4855 1.4863 1.4874 |
1.4870 1.4816 1.5166 |
Positive control Measurement 1 Measurement 2 Measurement 3 |
0.5413 0.5453 0.5385 |
0.3585 0.3446 0.3422 |
0.1999 0.2067 0.2032 |
0.1843 0.1793 0.1789 |
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- An in vitro skin corrosion test was conducted with X-19924 according to OECD 431 guideline and GLP principles. It is concluded that this test is valid and that X-19924 is not corrosive in the in vitro skin corrosion test under the experimental conditions described in this report.
NOTE: Any of data in this dataset are disseminated by the European Union on a right-to-know basis and this is not a publication in the same sense as a book or an article in a journal. The right of ownership in any part of this information is reserved by the data owner(s). The use of this information for any other, e.g. commercial purpose is strictly reserved to the data owners and those persons or legal entities having paid the respective access fee for the intended purpose.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.