Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
The determination was carried out using a closed cup flash point tester, using a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 21 April 2017 Experimental completion date: 04 July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
The determination was carried out using a closed cup flash point tester, using a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Other quality assurance:
other: Internal QA
Type of method:
closed cup
Remarks:
The determination was carried out using a closed cup flash point tester
Flash point apparatus:
Setaflash apparatus
Remarks:
Setaflash 30000-0 flash point tester
Specific details on test material used for the study:
Appearance/Physical state: Clear amber viscous liquid
Structure: The sponsor provided a structure on which the predictions of explosive and oxidizing properties were made. However, they wish the structure to remain confidential and therefore it has been omitted from this report.
Purity: 100% product
Expiry date: 24 June 2018
Storage conditions: Room temperature in the dark
Key result
Flash point:
231.1 °C
Atm. press.:
100.9 kPa
Remarks on result:
other: Corrected flash point
Flash point:
231 °C
Atm. press.:
100.9 kPa
Remarks on result:
other: Observed flash point
Interpretation of results:
GHS criteria not met
Remarks:
The flammability of the test item was assessed in accordance with EU Method A9. The test item has been determined not to have a flash point below 300 °C. Therefore, the test item does not meet the criteris for classification.
Conclusions:
The flash point of the test item has been determined to be 231 ± 2 °C
Executive summary:

Flash Point. 231 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

The flash point of the test item has been determined to be 231 ± 2 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
231 °C

Additional information

No additional data.