Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Description of first aid measures
General advice:
Move out of dangerous area. Consult a physician. Show this safety data sheet to the doctor in attendance. Do not leave the victim unattended.
If inhaled:
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
In case of skin contact:
Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. If on skin, rinse well with water. If on clothes, remove clothes.
In case of eye contact:
Small amounts splashed into eyes can cause irreversible tis-sue damage and blindness.In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
If swallowed:
Keep respiratory tract clear. Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.
Most important symptoms and effects, both acute and delayed
Risks:
Causes serious eye damage. Causes severe burns.
Indication of any immediate medical attention and special treatment needed
Treatment:
Basic aid, decontamination, symptomatic treatment.
Fire-fighting measures
Extinguishing media
Suitable extinguishing media:
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Hazardous combustion products:
Carbon dioxide (CO2), Carbon monoxide
Advice for firefighters
Special protective equipment for firefighters:
Wear self-contained breathing apparatus for firefighting if nec-essary.
Further information:
Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Personal precautions:
Use personal protective equipment.
Environmental precautions
Environmental precautions:
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods and material for containment and cleaning up
Methods for cleaning up:
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.
Reference to other sections
For personal protection see section exposure controls/personal protection.
Handling and storage
Precautions for safe handling
Advice on safe handling:
Avoid inhaling vapours. Avoid contact with skin and eyes. For personal protection see section exposure controls/personal protection. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.
Advice on protection against fire and explosion:
Normal measures for preventive fire protection.
Hygiene measures:
When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers:
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully re-sealed and kept upright to prevent leakage. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards.
Recommended storage temperature: > 60 °C
Further information on storage stability:
No decomposition if stored and applied as directed.
Specific end use(s)
Specific use(s): No data available
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- 2920
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- 2920
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- 2920
Shipping information
- Proper shipping name and description:
- CORROSIVE LIQUID, FLAMMABLE, N.O.S.
(ISOPROPYL METHYLPHENOL)
- Labels:
- 8, 3
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- 2920
Shipping information
- Proper shipping name and description:
- Corrosive liquid, flammable, n.o.s.
- Labels:
- 8, 3
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Exposure controls
Personal protective equipment
Eye protectio:
Tightly fitting safety goggles. Wear face-shield and protective suit for abnormal processing problems.
Hand protection
Material: Polychloroprene - CR, Wearing time: < 60 min
Material: Fluorinated rubber - FKM, Wearing time: < 60 min
Material: Polyvinyl chloride - PVC, Wearing time: < 60 min
Remarks: The suitability for a specific workplace should be discussed with the producers of the protective gloves. After contamina-tion with product change the gloves immediately and dispose of them according to relevant national and local regulations
Skin and body protection:
Impervious clothing. Choose body protection according to the amount and con-centration of the dangerous substance at the work place.
Respiratory protection:
Vapour respirator if product forms vapour/aerosol.
Filter type:
Combined inorganic and acidic gas/vapour, ammonia/amines and organic vapour type (ABEK)
Stability and reactivity
Reactivity
No specific test data related to reactivity available for this product or its ingredients.
Chemical stability
Stable under normal conditions.
Possibility of hazardous reactions
Hazardous reactions:
Under normal conditions of storage and use, hazardous reac-tions will not occur.
Conditions to avoid
Conditions to avoid: No data available
Incompatible materials
Materials to avoid:
No specific data.
Hazardous decomposition products
No hazardous decomposition products are known.
Disposal considerations
Waste treatment methods
Product:
The generation of waste should be avoided or minimised wherever possible.
Where possible recycling is preferred to disposal or incinera-tion.
Wastedisposal should be in accordance with existing federal state, provincial and or local environmental controls
Do not contaminate ponds, waterways or ditches with chemi-cal or used container.
Dispose of as hazardous waste in compliance with local and national regulations.
The product should not be allowed to enter drains, water courses or the soil.
Dispose of wastes in an approved waste disposal facility.
Send to a licensed waste management company.
Contaminated packaging:
Empty remaining contents.
Dispose of as unused product.
Do not re-use empty containers.
Do not burn, or use a cutting torch on, the empty drum.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.