Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures

General advice:

Move out of dangerous area. Consult a physician. Show this safety data sheet to the doctor in attendance. Do not leave the victim unattended.

If inhaled:

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

In case of skin contact:

Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. If on skin, rinse well with water. If on clothes, remove clothes.

In case of eye contact:

Small amounts splashed into eyes can cause irreversible tis-sue damage and blindness.In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

If swallowed:

Keep respiratory tract clear. Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.

Most important symptoms and effects, both acute and delayed

Risks:

Causes serious eye damage. Causes severe burns.

Indication of any immediate medical attention and special treatment needed

Treatment:

Basic aid, decontamination, symptomatic treatment.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media:

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Special hazards arising from the substance or mixture

Hazardous combustion products:

Carbon dioxide (CO2), Carbon monoxide

Advice for firefighters

Special protective equipment for firefighters:

Wear self-contained breathing apparatus for firefighting if nec-essary.

Further information:

Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

Personal precautions:

Use personal protective equipment.

Environmental precautions

Environmental precautions:

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up

Methods for cleaning up:

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.

Reference to other sections

For personal protection see section exposure controls/personal protection.

Handling and storage

Precautions for safe handling

Advice on safe handling:

Avoid inhaling vapours. Avoid contact with skin and eyes. For personal protection see section exposure controls/personal protection. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.

Advice on protection against fire and explosion:

Normal measures for preventive fire protection.

Hygiene measures:

When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.

Conditions for safe storage, including any incompatibilities

Requirements for storage areas and containers:

Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully re-sealed and kept upright to prevent leakage. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards.

Recommended storage temperature: > 60 °C

Further information on storage stability:

No decomposition if stored and applied as directed.

Specific end use(s)

Specific use(s): No data available

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
2920
Shippingopen allclose all
Labels:
8, 3
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
2920
Shippingopen allclose all
Labels:
8, 3
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
2920
Shipping information
Proper shipping name and description:
CORROSIVE LIQUID, FLAMMABLE, N.O.S.
(ISOPROPYL METHYLPHENOL)
Labels:
8, 3
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
2920
Shipping information
Proper shipping name and description:
Corrosive liquid, flammable, n.o.s.
Labels:
8, 3
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure controls

Personal protective equipment

Eye protectio:

Tightly fitting safety goggles. Wear face-shield and protective suit for abnormal processing problems.

Hand protection

Material: Polychloroprene - CR, Wearing time: < 60 min

Material: Fluorinated rubber - FKM, Wearing time: < 60 min

Material: Polyvinyl chloride - PVC, Wearing time: < 60 min

Remarks: The suitability for a specific workplace should be discussed with the producers of the protective gloves. After contamina-tion with product change the gloves immediately and dispose of them according to relevant national and local regulations

Skin and body protection:

Impervious clothing. Choose body protection according to the amount and con-centration of the dangerous substance at the work place.

Respiratory protection:

Vapour respirator if product forms vapour/aerosol.

Filter type:

Combined inorganic and acidic gas/vapour, ammonia/amines and organic vapour type (ABEK)

Stability and reactivity

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Chemical stability

Stable under normal conditions.

Possibility of hazardous reactions

Hazardous reactions:

Under normal conditions of storage and use, hazardous reac-tions will not occur.

Conditions to avoid

Conditions to avoid: No data available

Incompatible materials

Materials to avoid:

No specific data.

Hazardous decomposition products

No hazardous decomposition products are known.

Disposal considerations

Waste treatment methods

Product:

The generation of waste should be avoided or minimised wherever possible.

Where possible recycling is preferred to disposal or incinera-tion.

Wastedisposal should be in accordance with existing federal state, provincial and or local environmental controls

Do not contaminate ponds, waterways or ditches with chemi-cal or used container.

Dispose of as hazardous waste in compliance with local and national regulations.

The product should not be allowed to enter drains, water courses or the soil.

Dispose of wastes in an approved waste disposal facility.

Send to a licensed waste management company.

Contaminated packaging:

Empty remaining contents.

Dispose of as unused product.

Do not re-use empty containers.

Do not burn, or use a cutting torch on, the empty drum.