Registration Dossier

Administrative data

Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Justification for type of information:
Flammable liquid. Flammability derived from flash point (and boilling point).
Cross-reference
Reason / purpose:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to
Guideline:
other: ASTM D 92
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Cleveland open cup
Key result
Flash point:
53 °C
Atm. press.:
101 325 Pa
Conclusions:
The flash point of octan-3-one is 53°C.
Executive summary:

The test item octan-3 -one has a flash point of 53°C according to the guideline ASTM D 92 using a Cleveland open cup method.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion