Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
Reaction products of diazotized 4-amino-6-[(4-aminophenyl)diazenyl]-3-[(4-aminophenyl)diazenyl]-5-hydroxynaphthalene-2,7-disulfonic acid, coupled with benzene-1,3-diamine, sodium salts
EC Number:
812-037-7
Cas Number:
1793011-72-9
Molecular formula:
Unknown for all components
IUPAC Name:
Reaction products of diazotized 4-amino-6-[(4-aminophenyl)diazenyl]-3-[(4-aminophenyl)diazenyl]-5-hydroxynaphthalene-2,7-disulfonic acid, coupled with benzene-1,3-diamine, sodium salts
Test material form:
solid

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

The flame of the gas burner did ignite the test item pile. The test item glowed, burned with a yellow flame, emitted yellow sparks and turned into a black charred residue. Grey smoke was observed. After removal of the ignition source, the flame extinguished within 1 second and no propagation of combustion was observed.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The preliminary screening test was performed for the determination of the flammability of substance. No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered not flammable.