Registration Dossier

Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given (Certificate of Analysis)
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2592 (Determination of flash and fire points - Cleveland open cup method)
Version / remarks:
ASTM D92
GLP compliance:
no
Type of method:
closed cup
Remarks:
and open cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks:
and Cleveland
Key result
Flash point:
263 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: closed cup
Remarks:
mean value of five determinations
Key result
Flash point:
278 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: open cup
Remarks:
mean value of five determination

There are no values given for pressure but assumed to be measured at normal pressure (1013 hPa).

Description of key information

263 °C at ca. 1013 hPa (ASTM D93, Pensky-Martins Closed Cup)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
263 °C

Additional information

278 °C at ca. 1013 hPa (ASTM D92, Cleveland Open Cup)