Registration Dossier

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report Date:
2020

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 105 (Water Solubility)
GLP compliance:
no
Type of method:
flask method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Water solubility
Water solubility:
> 1 000 g/L
Conc. based on:
test mat.
Incubation duration:
>= 1 - <= 5 min
Temp.:
22.5 °C
pH:
< 3.89
Details on results:
In the preliminary test 0,1 g test item was dissolved in 0,1 ml purified water. Few minutes the solution was clearness.

Applicant's summary and conclusion